Showing 97–104 of 767 results

Filter»

Testing & Measuring


  • DC Power Supply


    • 600W / 1200W / 2400W / 5000W.
    • Wide Range of Voltage & Current Combinations with Constant Power.
    • Auto Sequencing Programming: 10 Programs / 100 Sequences / 8 bit TTL.
    • Soft Panels for Instrument Control and.

  • DC SIGNAL SOURCE   SS7012


    • DC voltage and current signal generator and tester for routine maintenance of standard devices.
    • Perform maintenance or loop tests of instrumentation systems.
    • Constant DC V and DC A source.
    • ±25 V, ±25 mA.
    • Thermoelectric power generation, K, E, J, T, R,S, B, N thermocouple.
    • Measure DC V and DC A.

  • Defibrillator Pulse External Pacer Analyzer Fluke Biomedical 6000D/ 7000DP


    • Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility.
    • AED technology compatibility.
    • First-class measurement accuracy ± 1 % of reading + 0.1 J.
    • Intuitive user interface and backlight, easy-to-read display.
    • Portable, rugged, easy to carry.

  • Didactic Training system for Analogue Communications Promax EC-696


    • MODULATIONS: AM, FM, PWM, FDM.
    • INPUTS / OUTPUTS: Generator, microphone / Oscilloscope, headphones.
    • TRANSMISSION: Two-wire, coaxial, Fibre Optics, Infra Red & Radio.

  • DIFFERENTIAL PROBE   9322


    • Measure high voltage with Hioki Memory HiCorders.
    • Analyze potential differences included in common mode voltages, such as IGBT.
    • Inspect commercial power line waveforms, such as on 400V power lines.
    • For up to 2 kV DC or 1 kV AC.
    • Frequency bandwidth up to 10MHz.

  • DIFFERENTIAL PROBE   P9000


    •  Isolated testing of high voltage signals.
    • Observe both instantaneous or RMS waveforms.
    • Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02).
    • For use with input of up to 1 kV AC/DC.
    • Requires separate power supply.

  • Digital Electrical Safety Tester Fluke Biomedical LT544


    • Small, lightweight, self-contained portable instrument.
    • Universal Power Supply. Input voltage from 85 - 265 VAC.
    • Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length.
    • Test method complies with AAMI load per ANSI/AAMI ES1-1993.

  • Digital Ford Code Reader (1981 – 1995)


    Safely and easily access on-board computer to read engine codes and perform self-test functions on most Ford, Lincoln, Mercury vehicles (domestic cars & trucks) from 1982 to 1995.