Testing & Measuring


  • RIGOL DSG830 RF Signal Generator 3GHz


    • DSG815 9 kHZ to 1,5 GHz.
    • DSG830 9 kHZ to 3 GHz.

  • RTD Temperature Calibrator Fluke 712


    • -200 to 800ºC Range Measure / simulate RTD (Pt 100).
    • 0 to 3200 Ω Range Measure / simulate resistance.
    • 0.1 Ω, 0.1 ºC Resolution.

  • SAFETY TEST DATA MANAGEMENT SOFTWARE   9267


    •  Pair with electrical safety testers to improve work efficiency and data management.
    • PC software for use with HIOKI electrical safety testers.
    • Inspect, record and save measurement data according to electrical safety standards controlling electrical safety measuring instruments.
    • Test insulation, withstand voltage (hipot), protective continuity, and leakage current.

  • Safety Tester for Photovoltaic Systems HT PVCHECK


    • Safety test of PV installation.
    • Continuity test on protective conductors with 200mA.
    • Insulation test with test voltage of 250, 500, 1000VDC.
    • DC voltage.
    • DC current.
    • DC Power.
    • Solar irradiation [W/m2] with reference cell.

  • Seba BPS 5000-d Burn and Proof Test System on Medium Voltage Cables BPS-5000d BPS500d BPS 5000d-VLF


    • Easy-go single button operation.
    • Protocolling of the test results.
    • Data transfer via Bluetooth.
    • DC burn current up to 6 A.
    • AC burn current up to 110 A.
    • Sheath fault pinpoiting mode.

  • Seba Digiflex Com Reflectometer Fault Locating on Metallic Telecomm Lines, Coaxial and Power Cables


    • Measuring range from 5 m up to 30 km.
    • Line comparison with 2 measuring inputs.
    • High resolution in the near and far range.
    • Weatherproof case.
    • Solid housing for rugged fi eld use.

  • Seba digiPHONE+ ESG NT Pinpointing acoustic pinpointing set for steath fault location in underground cables


    • Perfect acoustic quality and noise immunity.
    • Automatic filtration of interfering signals.
    • Automatic zero calibration, no adjustments necessary.
    • History mode.
    • Acoustic and step voltage fault location in one device.
    • BNR technology for perfect acoustic quality and noise immunity.
    • Automatic filtration of interfering signals.
    • Automatic setting of all parameters, no adjustments necessary.

  • Seba digiPHONE+ Surge wave receiver for acoustic and electromagnetic fault pinpointing in cables


    • Perfect acoustic quality and noise immunity.
    • Automatic mute function to protect your ears.
    • Bright, transflective sun readable display.
    • Easiest handling with automatic adjustment.
    • Earphone volume limitation to 84 dB(A).