Showing 9–16 of 50 results
Cable Route Tracking & Identification
-
Seba digiPHONE+ ESG NT Pinpointing acoustic pinpointing set for steath fault location in underground cables
- Perfect acoustic quality and noise immunity.
- Automatic filtration of interfering signals.
- Automatic zero calibration, no adjustments necessary.
- History mode.
- Acoustic and step voltage fault location in one device.
- BNR technology for perfect acoustic quality and noise immunity.
- Automatic filtration of interfering signals.
- Automatic setting of all parameters, no adjustments necessary.
-
Seba digiPHONE+ Surge wave receiver for acoustic and electromagnetic fault pinpointing in cables
- Perfect acoustic quality and noise immunity.
- Automatic mute function to protect your ears.
- Bright, transflective sun readable display.
- Easiest handling with automatic adjustment.
- Earphone volume limitation to 84 dB(A).
-
Seba Easyflex Com Reflectometer Locate Faults on Cu Telecommunication, Signal and Power Cables
- Test range 50 m ... 15000 m.
- High local resolution of 5 cm in 50 m test range.
- Simple operation due to menu prompting and help functions.
- Easy evaluation of the traces by simultaneous display of zoom and total view (split-screen).
- Large display with backlight.
- Individual measurement, continuous measurement and averaging.
- Measuring connections suitable for live voltage up to 250 V.
-
Seba Fault Sniffer for detection of burning gases from Fault Cables Underground
- Customers can stay connected.
- Fault location with no supply interrupt.
- Reliable avoidance of incorrect excavations.
- Fast and easy location of faults.
- Can be used on straight or branched networks.
- Handy size, easy to transport.
- No pre-location required.
- Accuracy in the decimetre range.
- Sensitive to several specifi c gases and therefore suitable for any insulation material.
-
Seba KMT BT 500 IS-1 Cable Fault Converter
- Overload protection.
- Automatic discharge.
- Burning of high resistive faults.
- Low- potential free voltage avoids damage to other conductors.
- Adjustable current limiter.
-
Seba KMT BT 500 IS-1 Cable Fault Converter
- Overload protection.
- Automatic discharge.
- Burning of high resistive faults.
- Low- potential free voltage avoids damage to other conductors.
- Adjustable current limiter.
-
Seba KMT CDS Cable Diagnostic System for three phase IRC and RVM diagnostics
- Absolutely non-destructive condition evaluation of PE / XLPE / paper-oil insulated cable systems.
- Simple operation and automatic measurement procedures.
- Three-phase parallel measurement for current and voltage – duration of a complete measurement 1 hour.
- Extended dynamic range for IRC measurement for long cable segments.
- Measurement of charging current during formation.
-
Seba KMT CI LCI Cable Identifier test set